Sign In | Join Free | My himfr.com
Home > Fisher Gas Regulator >

High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service

Suzhou Ephood Automation Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service from wholesalers
     
    Buy cheap High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service from wholesalers
    • Buy cheap High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service from wholesalers
    • Buy cheap High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service from wholesalers
    • Buy cheap High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service from wholesalers

    High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service

    Ask Lasest Price
    Brand Name : Fisher
    Model Number : 1098-EGR
    Price : USD5800Each One Set
    Payment Terms : T/T
    Supply Ability : 200sets Every Month
    Delivery Time : 8weeks
    • Product Details
    • Company Profile

    High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service

    High Flow Rate Fisher Gas Regulator 1098-EGR Pressure Reducing Regulator

    For Corrosive Environments And Oxygen Service

    Emerson Group Fisher Brand Make Type 1098-EGR Pressure Reducing Regulators

    Fisher Type 1098-EGR pressure gas regulator provide economical and accurate pressure control in a wide variety of applications.

    Natural gas distribution systems; fuel gas supply to industrial boilers, furnaces, ovens, and mixers; and large commercial / industrial establishments such as shopping centers and schools. They are also used in plant air service and in liquid service.


    Table 1. Outlet Pressure Ranges and Spring Selection

    Outlet Pressure Range (PSI/BAR)Spring Part NumberSpring Color
    3 to 15(0,21 to 1,03)
    3 to 20(0,21 to 1,38)
    5 to 35(0,34 to 2,41)
    30 to 60(2,07 to 4,14)
    35 to 100(2,41 to 6,90)
    80 to 150(5,52 to 10,3)
    1D892327022
    1D751527022
    1D665927022
    1D745527142
    1E543627142
    1P901327142
    Red
    Silver
    Blue
    Green
    Yellow
    Brown
    1. All springs can be backed off to 0 psig (0 bar). For the highest capacity and most accurate control, use the lowest-range spring that can be adjusted to the required setpoint.
    2. C Cannot be used in anhydrous ammonia (NH3) applications.

    Features

    Versatility

    Body Side Connection

    Easy Maintenance

    UL Listed


    Specifications

    Body Size and End Connection Style

    End: 1/2-inch NPT
    Gauge Outlet: 1/4-inch NPT

    Maximum Inlet Pressure
    250psi /17.2Bar

    Spring Range

    5~35psig (0.34~2.41bar)

    Pressure Registration
    Internal

    Temperature Capabilities
    -20º to 150ºF / -29º to 66ºC


    1. Use qualified personnel when installing, operating, and maintaining these regulators. Before installation inspect for damage.

    Make sure there is not any foreign material in the regulator and all tubing and piping are clean and unobstructed.

    2. If installing the regulator at an outside location, point the spring case vent in the downward direction to protect it from getting

    plugged or from collecting moisture, corrosive chemicals, or other foreign materials. Spring case vent orientation may be changed

    by rotating the spring case with respect to the regulator body.

    3. Install the regulator so that flow is from the IN to OUT connection as marked on the regulator body.

    4. To remotely vent the spring case, remove the screen, if present, and connect 1/4-inch NPT piping or tubing to the spring case

    connection. The piping or tubing should vent the spring case to a safe location, have as few bends as possible, and have a screened

    vent on its exhaust end that is weather resistant and always pointed in the downward direction.

    5. Like most regulators, 64 Series regulators have outlet pressure ratings lower than inlet pressure ratings. Although types with

    internal relief include limited downstream overpressure protection, all types may require additional relief protection for some service

    conditions if the actual inlet pressure can exceed the regulator outlet pressure rating or the pressure ratings of any downstream

    equipment. Inspect a regulator periodically and after any overpressure condition.

    6. Each regulator is factory-set for the pressure setting specified on the order. If no setting is specified, outlet pressure is

    factory-set at the midrange of the control spring.



    Quality High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Ephood Automation Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)